Flush Door

LEXI flush door is a durable product known for its excellent quality, exceptional finish and unique dimensional stability. It is made of hardwood frames and accurate battens. It is evenly constructed with same species of timber that matters the most in providing longer life. Stiles , rails and wooden strips are kiln-seasoned and are treated with eco-friendly preservatives.BWP grade of Phenol Formaldehyde resin is used for bonding the layers. The phenolic resin conforms to IS 848:1974 specifications, which is mixed with unique additives to enhance the protection characteristics.

LEXI Flush doors have an extra lock rail that procides sufficient strength for fitting of hinges and anti deviation resistance. The complete testing of Flush door enables the company to render assured strength, safety and peace.

Applications: Standard Sizes: Modular and non modular sizes single and double leaf as per customer requirements.
                        Standard Thickness: 25mm,30mm,32mm,35mm,38mm,40mm and 45mm.

Technical Specifications(IS:303)
Sr. No.
Test
ISI Requirement
Observed Value
1
Dimension
Length, Width - + 5 mm
Thickness + 1 mm
Within limits
2
Squareness
Deviation not more than 1mm on a length of 500mm
Deviation below 1 mm
3
General Flatness
Twist,cupping,warping not to exceed 6mm
4
Local Planeness
Depth of deviation at any point to be less than 0.5 mm
Within limits
5
Impact Indentation Test
Depth of indentation not to exceed 0.2 mm
Within limits
6
Edge Loading Test
Deflection of edge with max. To be less than 5 mm
Within limits
7
Shock Resistance Test
No visible defect after test
No visible defects
8
Buckling Test
Initial deflection - < 50mm
Residual deflection - < 5mm
Within limits
9
Slamming Test
No visible damage after test
No visible damage
10
Misuse Test
No deformation after test
No deformation
11
Varying Humidity Test
No visible warping,twisting or de-lamination
No such defects observed
12
End Immersion Test
No de-lamination at the end
No de-lamination
13
Knife Test
Minimum Pass Standard
Excellent
14
Glue Adhesion Test
No de-lamination
No de-lamination
15
Screw Withdraw Test
Load to withdraw screw to be more than 1000 N
Load - > 1000 N